T: +34 965 95 95 11 · E: info@futurasmus-knxgroup.com
select language flag

The most complete solution for smartmetering in KNX
We have gathered and arranged the best choice of KNX counters from different brands for your convenience. Now it is easier to find what you need for a more efficient management of consumption.
The possibility to measure and monitor the different consumption values generated in a building becomes increasingly important. The goal is to drastically reduce them! In Futurasmus KNX Group we are fully aware and we would like to introduce a complete solution with several consumption counters (energy, water, gas, calories/freezeries and interfaces to other systems) to achieve that goal.


esquema
Contadores Energía Interfaces Contadores Agua Contadores Gas Calorimetros Actuador Actuador Actuador Electrónico Actuador Actuador Actuador Electrónico Sonda Sonda Sonda Sonda Controlador de Estancias Controlador de Estancias Controlador de Estancias Controlador de Estancias Controlador de Estancias Controlador de Estancias Sensor de Radiación Global Interfaces


ENERGY COUNTERS



Energy counters proved real energy values (kWh and Wh), power (W), current (A), voltage (V), as well as the power factor of a single-phase or three-phase electrical circuit. On top of that, they have a resettable absolute and relative counter, the possibility to choose from different fees according to off-peak/peak times, etc.

We can also find direct- or Transformer-measurement counters for toroidal transformers.

Web Code Order No. Connection Quadrant Current per phase Transformer Type
12387 87765 Direct 1 75A - Three-Phase
12395 87773 Transformer 1 - /1A o /5A Three-Phase
12388 87766 Direct 4 75A - Three-Phase
12396 87774 Transformer 4 - /1A o /5A Three-Phase
12390 87763 Direct 1 32A - Single-Phase
18093 87735 Direct 4 100A - Three-Phase
WATER COUNTERS



Water counters provide accumulated consumption values both in m3 or litres; they have resettable absolute and relative counters, the possibility to set the invoicing date, possibility to initialize at a specific value, etc.

In Futurasmus you can find a great number of water counters with different nominal flows, nominal diameter (ND), diameters and lengths so as to match the needs of any given installation.

Web Code Order No. Rated flow DN Diameter Length Max.
Temperature
Instant
Consumption
m3 or liter
8512 60201-75124015 1,5m³/h 15 G ¾" 80 mm 30°C Yes
8514 60201-75124115 1,5m³/h 15 G ¾" 110 mm 30°C Yes
10201 85101 1,5m³/h 15 G ¾" 80 mm 40°C No
10202 85102 1,5m³/h 15 G ¾" 110 mm 40°C No
8513 60201-75124515 1,5m³/h 15 G ¾" 80 mm 90°C Yes
8515 60201-75124615 1,5m³/h 15 G ¾" 110 mm 90°C Yes
10204 85111 1,5m³/h 15 G ¾" 80 mm 90°C No
10205 85112 1,5m³/h 15 G ¾" 110 mm 90°C No
12584 85301 1,6m³/h 15 G ¾" 80 mm 30°C Yes
12585 85302 1,6m³/h 15 G ¾" 80 mm 90°C Yes
12586 85303 1,6m³/h 15 G ¾" 110 mm 30°C Yes
12587 85304 1,6m³/h 15 G ¾" 110 mm 90°C Yes
12588 85305 1,6m³/h 15 G ¾" 130 mm 30°C Yes
12589 85306 1,6m³/h 15 G ¾" 130 mm 90°C Yes
17063 85319 2,5m³/h 20 G 1" 105 mm 90°C Yes
8516 60201-75124025 2,5m³/h 20 G 1" 130 mm 30°C Yes
12594 85315 2,5m³/h 20 G 1" 130 mm 30°C Yes
17061 85317 2,5m³/h 20 G 1" 190 mm 30°C Yes
10203 85103 2,5m³/h 20 G 1" 130 mm 40°C No
10207 85140 2,5m³/h 20 G 1" 190 mm 40°C No
17062 85320 2,5m³/h 20 G 1" 105 mm 90°C Yes
8517 6201-75124525 2,5m³/h 20 G 1" 130 mm 90°C Yes
12595 85316 2,5m³/h 20 G 1" 130 mm 90°C Yes
10206 85113 2,5m³/h 20 G 1" 130 mm 90°C No
10210 85150 2,5m³/h 20 G 1" 190 mm 90°C No
17064 85318 2,5m³/h 20 G 1" 190 mm 90°C Yes
10208 85141 6m³/h 25 G 1"-1/4" 260 mm 40°C No
10211 85151 6m³/h 25 G 1"-1/4" 260 mm 90°C No
10209 85142 10m³/h 40 G 2" 300 mm 40°C No
10212 85152 10m³/h 40 G 2" 300 mm 90°C No
*Please, ask for other dimensions
GAS COUNTERS



Gas counters deliver the accumulated consumption in m3 or litres; they have resettable absolute and relative counters, decremental counter that can start at any given value and sends alert when reaching 0, the possibility to set the invoicing date, etc.

In Futurasmus you can find a great number of gas counters with different nominal flows and nominal diameter (ND) so as to match the needs of any given installation.

Web Code Order No. Rated flow DN Adapter
15767 85802 0.04-6m3/h 25 Simple
15762 85805 0.04-6m3/h 20 Double
10181 85801 0.04-6m3/h 25 Double
15763 85808 0.06-10m3/h 32 Double
15764 85807 0.10-16m3/h 40 Double
15765 85804 0.16-25m3/h 40 Double
15766 85809 0.26-40m3/h 50 Double
18120 85812 0,04-6 m³/h 25 Simple
18121 85814 0,06-10 m³/h 25 Simple
18122 85816 0,10-16 m³/h 40 Simple
18123 85818 0,16-25 m³/h 40 Simple
10199 85811 0,4-6 m³/h 25 Double
18124 85813 0,06-10 m³/h 25 Double
18128 85815 0,10-16 m³/h 40 Double
18128 85815 0,10-16 m³/h 40 Double
18129 85817 0,16-25 m³/h 40 Double
*Please, ask for other dimensions
CALORIES OR CALORIES/FREEZERIES COUNTERS



HEATING
Calories counters supply the current heating energy value in kW, the stored value in kWh, the stored water consumption in m3 and litres, efficiency in W, instant consumption in m3/h, supply- and return-flow-temperature and invoicing functionality.

Futurasmus you can find a great number of calories counters with different nominal flows, nominal diameter (ND), diameters and lengths so as to match the needs of any given installation.

Available with both dry and wet temperature probes.

Web Code Order No. Rated flow DN Diameter Length Probe
9050 60101-85373106 0.6m3/h 15 G ¾" 110mm Dry
9051 60101-85473106 0.6m3/h 15 G ¾" 110mm Wet
11763 60101-85373115 1.5m3/h 15 G ¾" 110mm Dry
11765 60101-85473115 1.5m3/h 15 G ¾" 110mm Wet
11764 60101-85373125 2.5m3/h 20 G 1" 130mm Dry
9050 60101-85473125 2.5m3/h 20 G 1" 130mm Wet
*Please, ask for other dimensions


HEATING/COOLING
Calories or Calories/Freezeries counters supply the stored energy value (both heat and cooling in MWH and kWh). Apart from the absolute counter, it has a resettable relative counter, decremental counter that can start at any given value and sends alert when reaching 0, water consumption in m3 or litres, instant consumption in m3/h, supply- and return-flow-temperature, invoicing functionality, etc.

In Futurasmus you can find a great number of calories/freezeries counters with different nominal flows, nominal diameter (ND), diameters and lengths so as to match the needs of any given installation.

Web Code Order No. Rated flow DN Diameter Length
15804 84901 0.6m3/h 15 G ¾" 110mm
15805 84902 1.5m3/h 15 G ¾" 110mm
15806 84903 1.5m3/h 15 G ¾" 165mm
15807 84904 0.6m3/h 20 G 1" 130mm
15808 84905 1.5m3/h 20 G 1" 130mm
15809 84906 1.5m3/h 20 G 1" 165mm
15810 84907 0.6m3/h 20 G 1" 190mm
15811 84908 1.5m3/h 20 G 1" 190mm
15812 84909 2.5m3/h 20 G 1" 190mm
15813 84910 3.5m3/h 25 G 5/4" 260mm
15814 84911 6.0m3/h 25 G 5/4" 260mm
15815 84912 10m3/h 40 G 2" 300mm
*Please, ask for other dimensions


More about calories counters
GATEWAYS

If your KNX system has already got non-KNX consumption counters, it might not be possible to install new ones that are directly KNX In that case, we are glad to offer a series of interfaces to integrate the former counters in the KNX system in a very easy way. Find out how to monitor the consumption of electricity, heat, water or gas.

S0 PULSES
KNX interfaces for consumption counters with S0 pulses output. A battery allows its further operation for over 5 years without KNX connection. Available as DIN rail device or IP65.
Web Code Order No. Mounting IP Rating
9542 60201101 Surface 65
10955 60201201 Surface 65
10981 60201102 DIN rail 20
10982 60201202 DIN rail 20


M-BUS
KNX interfaces for M-BUS ("Meter-Bus") consumption counters. They can control up to 3 devices per interface and a total of 32 M-bus data points. Available as DIN rail device or IP65.
Web Code Order No. Mounting IP Rating
11171 60400001 Surface 65
11172 60400002 DIN rail 20


MODBUS
These bidirectional gateways have been specially designed to monitor and control from KNX all parameters and functionality of ModBus systems and devices.

Available for ModBus RTU (serial port EIA232 or EIA485) or ModBus TCP (Ethernet)
Web Code Order No. Capability (points) Slaves For Communication
8999 IBOX-KNX-MBRTU-100 100 254 RTU Master EIA232 or EIA485
9112 IBOX-KNX-MBRTU-A 500 254 RTU Master EIA232 or EIA485
9113 IBOX-KNX-MBRTU-B 3000 254 RTU Master EIA232 or EIA485
9108 IBOX-KNX-MBTCP-100 100 5 TCP Master Ethernet
9109 IBOX-KNX-MBTCP-A 500 5 TCP Master Ethernet
9110 IBOX-KNX-MBTCP-B 4000 5 TCP Master Ethernet


BACnet
These bidirectional gateways have been specially designed to monitor and control from KNX all parameters and functionality of BACnet/IP systems and devices.
Web Code Order No. Manufacturer Capability (points) Supported BACnet/IP devices
10487 IBOX-KNX-BAC-100 Intesis 100 16
9111 IBOX-KNX-BAC-A Intesis 500 16
9107 IBOX-KNX-BAC-B Intesis 4000 16


OPTICAL
KNX Interfaces provided with an optical reader: depending on the energy counters protocol, they can read T1 / T2, A+ values, power, voltage and current.
Web Code Order No. Sensor
15780 87798 Included
15781 87797 Included for Kamstrup meters
ROOM CONTROLLERS



VERSO is the brand-new and powerful room controller by Iddero, with capacitive 4,3” touch display, for the visualization and control of KNX systems. From IDDERO manufacturer.

Available in black and white finishing.

Installation in vertical and horizontal format.

Main functions:
  • Up to 48 control functions, arranged in 6 configurable pages.
  • Additional “favourites” page that can be edited by the final user.
  • Customizable background images.
  • Time schedules (up to 48 channels, 4 programs per channel).
  • Alarm (max.48) monitoring with historical data.
  • Touch flicks: It allows the configuration of 5 quick actions within the energy saving mode.
  • Internal scenes controller.
  • Two independent thermostats.
  • 4 multifunction inputs which can be individually configured as binary or for a temperature probe.

Integrated temperature sensor.

Real time clock with backup battery.

Direct connection to the KNX bus.

Ultra-low energy consumption.

More room controllers
ANALOG IN-/OUTPUT 0-10V



The MDT Analog In-/Output is suitable to control devices with 0-10V inputs and to catch 0-20mA/0-10V measurement data.

All channels are gavanically isolated from the KNX bus and can be configured independently from each other as input or output.

The input voltage range is from 0-10V or from 2-10V, optionally the inputs can be operated as current loop with 0-20mA or 4-20mA.

Each input can be parameterized individually with the ETS.

Min/max, treshold and traffic light functions are available

The conversation of measuring unit and DPT can be parameterized.

The outpult voltage range is from 0-10V and can be controlled via 1Byte, 2Byte or 1Bit objects.

If the control value fails the emergency mode starts automatically. Each output has a day/night function to limit the control value.

The MDT Analog In-/Output is available in two types. As modular installation device or flush mounted device for fixed installations in dry rooms.

Web Code Order No. Mounting Input Output DIN Units
16746 AIO-0210V.01 Flush mounted 0-10V/2-10V - 0-20mA/20mA 0-10V 2
16747 AIO-0410V.01 DIN rail 0-10V/2-10V - 0-20mA/4-20mA 0-10V 4